User manual
Seite 6 von 8
Stand: August 2018 Z314-MG
5. Connecting
5.1. Control connections
Speed reference value: Terminal 1: GND
Terminal 2: wiper external potentiometer (10kOhm)
Terminal 3: 5V DC
Controller enable (RF): Terminal 4: Input 10-36V DC H/active
U
E2
: Terminal 5: Output (12-36V DC, <50mA) e.g. for
external switch for controller enable
Ready for operation (BTB): Terminal 6: digital output (12-36V DC, <50mA)