Datasheet
174 03/01
2-Line Filters B84142-A*-R
for Converters and Power Electronics
Typical circuit diagram
Technical data
Characteristics and ordering codes
Rated voltage V
R
250 V~, 50/60 Hz
Rated current I
R
Referred to 40 °C ambient temperature
Test voltage V
P
1770 V–, 2 s (line/line)
2700 V–, 2 s (lines/case)
Overload capability 1,5 · I
R
 for 3 min per hour or
2,5 · I
R
 for 30 s per hour
Leakage current I
leak
  at 250 V~, 50 Hz
Climatic category 25/100/21 (– 25
°C/+ 100 °C/21 days damp heat test)
in accordance with EN 60068-1
I
R
A
Terminal
cross section
mm
2
I
leak
mA
R
typ
mΩ
Approx.
weight
kg
Ordering code
10  4
< 8 18 0,55 B84142-A10-R
20  4
< 8 10 1,0 B84142-A20-R
30  6
< 8  5 1,0 B84142-A30-R
40  6
< 17  3,6 1,0 B84142-A40-R
50 16
< 26  1,8 2,5 B84142-A50-R
60 16
< 26  1,4 2,5 B84142-A60-R
L
N
SSB1515-U
N’
L’
LINE LOAD