EMC filters 2-line filters SIFI-E for high insertion loss Rated current 3 to 10 A Series/Type: B84115E Date: January 2006 EPCOS AG 2006. Reproduction, publication and dissemination of this data sheet and the information contained therein without EPCOS’ prior express consent is prohibited.
-line filters B84115E SIFI-E for high insertion loss Power line filters for 1-phase systems Rated voltage 250 V DC/AC, 50/60 Hz Rated current 3 to 10 A Construction ■ 2-line filters ■ Metal case ■ Polyurethane potting (UL 94 V-0) Features ■ Compact design ■ High insertion loss, even ■ ■ ■ ■ in the range below 100 kHz Optimized leakage current Cost-optimized construction Also for assembly on top-hat rails ENEC10, UL and CSA approval Applications ■ Switch-mode power supplies in – industrial electronics
2-line filters B84115E SIFI-E for high insertion loss Circuit diagram LINE L LOAD L’ N N’ SSB0270-8 Technical data and measuring conditions Rated voltage VR 250 V DC/AC, 50/60 Hz Rated current IR Referred to 40 °C ambient temperature Test voltage Vtest 1414 V DC, 2 s (line/line) 2700 V DC, 2 s (lines/case) Leakage current lleak At 230 V AC, 50 Hz Climatic category (IEC 60068-1) 25/085/21 (–25 °C/+85 °C/21 days damp heat test) Approvals EN 133200, UL 1283, CSA C22.2 No.
2-line filters B84115E SIFI-E for high insertion loss Case styles and dimensions Case style IR A Dimensions (mm) b1 b2 b3 b4 l1 A B K 3 3 3 50.8 31.5 60.4 70 50.8 31.5 — — 50.8 — — — 63.5 — — 89.5 38.1 28 63.5 74.7 84.5 89.5 38.1 28 79.
2-line filters B84115E SIFI-E for high insertion loss Case style B Case style B 3 A (B84115E0000B030) 6 and 10 A (B84115E0000B060, B110) 44.5 0.8 h1 0.8 159 133 153 3 2 Tab connector A6.3 x 0.8 142.9 h2 1 4 Tab connector A6.3 x 0.8 ø4.7 28±1 50.8 31.5 b1 b2 SSB0528-L-E ø4.7 Please read Cautions and warnings and Important notes at the end of this document.
2-line filters B84115E SIFI-E for high insertion loss Case style K 3 A (B84115E0000K030) 6 A (B84115E0000K060) b1 M4 x 5.5 40 40 44.5 0.8 16 17.8+0.8 h1 M4 Tab connector A6.3 x 0.8 3 133+0.8 1 101.6±0.3 4.7 13 13 Tab connector A6.3 x 0.8 19 60.4+0.1/ _ 0.5 70 3 _ 0.5 31.5 Panel cutout 28.5 _ 0.5 4 +1 3±1 20.5 ø4.5 28.5 40±0.2 31.5 50.8+1.5 SSB2178-8-E Panel cutout 20.5 ø4.5 28.5 40±0.2 Please read Cautions and warnings and Important notes at the end of this document.
2-line filters B84115E SIFI-E for high insertion loss Insertion loss (typical values at Z = 50 Ω) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) Filters for 3 A Filters for 6 A 100 dB B84115E0000*030 SSB0271-G α 100 dB B84115E0000*060 SSB0272-P α 80 80 60 60 40 40 20 20 0 10 4 10 5 10 6 10 7 0 10 4 Hz 10 8 f Filters for 10 A 100 dB B84115E0000*110 SSB0273-X α 80 60 40 20 0 10 4 10 5 10 6 10 7 H
EMC filters Cautions and warnings Important information Please read all safety and warning notes carefully before installing the EMC filter and putting it into operation (see ). The same applies to the warning signs on the filter. Please ensure that the signs are not removed nor their legibility impaired by external influences.
EMC filters Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned.