Datasheet
Test Reference Conditions of test Performance requirements
Damp heat,
steady
state
IEC
60384-14:2013
Test Ca
40 °C / 93% RH / 56 days
No visible damage
ΔC/C
0
≤ 5%
Δ tan δ ≤ 0.008 for C ≤ 1 μF
Δ tan δ ≤ 0.005 forC>1μF
Voltage proof
R
ins
≥ 50% of initial limit
Impulse
test
Endurance
IEC
60384-14:2013
3 impulses
Tb / 1.7 V
R
/ 1000 hours,
1000 V
RMS
for 0.1 s every hour
No visible damage
ΔC/C
0
≤ 10%
Δ tan δ ≤ 0.008 for C ≤ 1 μF
Δ tan δ ≤ 0.005 forC>1μF
Voltage proof
R
ins
≥ 50% of initial limit
Passive
flammability
IEC
60384-14:2013
Flame applied for a period of
time depending on capacitor
volume
B
Mounting guidelines
1 Soldering
1.1 Solderability of leads
The solderability of terminal leads is tested to IEC 60068-2-20, test Ta, method 1.
Before a solderability test is carried out, terminals are subjected to accelerated ageing (to
IEC 60068-2-2, test Ba: 4 h exposure to dry heat at 155 °C). Since the ageing temperature is far
higher than the upper category temperature of the capacitors, the terminal wires should be cut off
from the capacitor before the ageing procedure to prevent the solderability being impaired by the
products of any capacitor decomposition that might occur.
Solder bath temperature 235 ±5 °C
Soldering time 2.0 ±0.5 s
Immersion depth 2.0 +0/0.5 mm from capacitor body or seating plane
Evaluation criteria:
Visual inspection
Wetting of wire surface by new solder ≥90%,
free-flowing solder