Datasheet
Technical data
Reference standard: IEC 60384-14:2013 / UL 60384-14:2014. All data given atT=20°C, unless
otherwise specified.
Max. operating temperature T
op,max
+110 °C
Dissipation factor tan δ (in 10
-3
)
at 20 °C (upper limit values)
at 1 kHz 1.0
at 100 kHz 5.0
Insulation resistance R
ins
or time
constant τ =C
R
R
ins
at 20 °C,
rel. humidity ≤ 65% (minimum
as-delivered values)
30 000 MΩ
DC test voltage
4800 V, 2 s
The repetition of this DC voltage test may damage the capacitor. Special care must be taken in
case of use several capacitors in a parallel configuration.
Passive flammability category B
Maximum continuous AC voltage V
AC
750 V (50/60 Hz)
Rated AC voltage (UL
60384-14:2014)
500 V (50/60 Hz)
Maximum continuous DC voltage V
DC
3000 V
T
op
≤ 110 °C V
op
=V
AC
(continuously)
temperature
T
op
≤ 110 °C V
op
= 1.25 V
AC
(1000 h)
Damp heat test 56 days / 40 °C / 93% relative humidity
Limit values after damp heat test
Capacitance change ΔC/C ≤ 5%
Dissipation factor change Δ tan δ≤5.10
-3
(at 1 kHz)
≤ 1.0 10
-3
(at 100 kHz)
Insulation resistance R
ins
or time constant τ =C
R
R
ins
≥ 50% of minimum
as-delivered values
B81123
Y1/500VAC
Page5of19Please read Cautions and warnings and