Datasheet

246 10/02
Compact 105 °C
B43504
Specifications and characteristics in brief
Rated voltage
U
R
Surge voltage
U
S
200 450 VDC
1,15 ·
U
R
(for
U
R
250 VDC)
1,10 ·
U
R
(for
U
R
400 VDC)
Rated capacitance
C
R
Capacitance tolerance
47 2200 µF
± 20 % M
Dissipation factor tan δ
(20°C, 120 Hz)
U
R
400 VDC: tan δ 0,15
U
R
420 VDC: tan δ 0,20
Leakage current
I
L
(5 min, 20°C)
Self-inductance
ESL
Approx. 20 nH
Useful life Requirements:
105°C;
U
R
;
I
~
R
85°C;
U
R
;
I
~
max
40°C;
U
R
; 1,9 ·
I
~
R
> 3 000 h
> 6 500 h
> 200 000 h
C
/
C
± 30 % of initial value
tan δ≤ 3 times initial specified limit
I
L
initial specified limit
Failure percentage: 1 %
Failure rate: 40 fit ( 40 · 10
9
/h)
(for definiton fit, refer to chapter
Quality
, page 62)
Load life test
105 °C;
U
R
;
I
~
R
2 000 h Post test requirements:
C/C ± 20 % of initial value
tan δ≤ 2 times initial specified limit
I
L
initial specified limit
Voltage endurance test
105 °C;
U
R
2 000 h Post test requirements:
C
/
C
± 10 % of initial value
tan
δ≤ 1,3 times specified limit
I
L
initial specified limit
Vibration resistance To IEC 60068-2-6, test Fc:
displacement amplitude 0,35 mm, frequency range 10 55 Hz,
acceleration max. 5
g
, duration 3 × 2 h
IEC climatic category To IEC 60068-1:
U
R
400 VDC: 40/105/56 ( 40°C/+ 105°C/56 days damp heat test)
U
R
420 VDC: 25/105/56 ( 25°C/+ 105°C/56 days damp heat test)
Detail specification
Sectional specification
Similar to CECC 30301-809
IEC 60384-4
I
L
0,3 µA
C
R
µF
-------
U
R
V
-------
èø
æö
0,7
4 µA+