Datasheet

Typical applications
X2 class for interference suppression
"Across the line" applications
Climatic
Max. operating temperature: 110 °C
Climatic category (IEC 60068-1):
40/105/56 (ENEC10)
40/110/56 (ENEC15)
Construction
Dielectric: polypropylene (MKP)
Plastic case (UL 94 V-0)
Epoxy resin sealing (UL 94 V-0)
Features
Very small dimensions
Self-healing properties
RoHS-compatible
Halogen-free capacitors available on request
Terminals
Parallel wire leads, lead-free tinned
Special lead lengths available on request
Marking
Manufacturer's logo, lot number,
date code, rated capacitance (coded),
cap. tolerance (code letter),
rated AC voltage,
series number, sub-class (X2),
dielectric code (MKP), climatic category,
passive flammability category, approvals.
Delivery mode
Bulk (untaped)
Taped (Ammo pack or reel)
For taping details, refer to chapter
"Taping and packing"
Dimensional drawings
Drawing 1
Drawing 2
Dimensions in mm
P
1
= 20.3 mm
Lead
spacing
±0.4
Lead
diameter
d1 ±0.05
Type Drawing
10 0.6 B32921 1
15 0.8 B32922 1
22.5 0.8 B32923 1
27.5 0.8 B32924 1
37.5 1.0 B32926 1 / 2
1)
52.5 1.2 B32928 2
1) A few individual types only
EMI suppression capacitors (MKP) B32921C/D ... B32928C/D
X2 / 305 V AC
Page 2 of 24Please read Cautions and warnings and