User Manual
DESCRIPTION
This digital level is a highly versatile leveling tool
designed for fast, easy operation
● Measuring range of digital display: 4×90°
● Resolution of Digital Display : 0.05°
● Precision of Digital Display : ±0.1° at 0° and 90°
±0.2° at other angles
● Unit of measurement (°degrees / % / mm/m / IN/FT)
● VA screen, black color backlight, white characters LCD display
● Hold function
● 0°calibration
● High accuracy level bubble vial on the top, for leveling work
without ba
ttery
● V-groove on the measurement base, for easy attach to round
pipes
● Groove on the 2 sides housing, for easy doing the mark work
● Powerful built-in magnets on the base secures the attachment
to iron surface
● Battery type: 2x1.5V “AAA” batteries
● Working temperature: 0℃ ~ 40℃
● Storage temperature: -10℃ ~ 50℃
● Dimensions: 68*32*62mm(L*W*H)
● Weight: About 100g (Not containing batteries)
Product outlook
Operation instructions
1. Battery replacement
Remove the rear battery cover of the equipment by unscrewing the
battery cover retaining screw.
Open the battery case. Put two “AAA” batteries and close the case.
Your electronic level is now ready to use.
2. ON/OFF
Press ON/OFF button to turn the equipment on. Press and hold
ON/OFF button for about 3 seconds to turn off.
After about 3 minutes of non-using the equipment, it will
switch off automatically.
3. Level measurement
Turn on the equipment and put it to the level position for measuring.
Correct measuring Wrong measuring
4. Unit of measurement selection (°degrees / % / mm/m
IN/FT)
After switching on, the screen always shows the actual slope in
degree. By pressing the MODE button you can change the angles
unit display units from degrees (°) to percent (%), to (mm/m) to
pitch (in/ft). Pitch readings are in 1/8-inch/feet increments.
The
icon indicates the current angle’s position, either up
or down away from the horizontal or vertical position.
5. Angle measurement
If the equipment isn’t in level, it will display a value on the screen.
Short press ZERO button to set current angle to zero, keep the
equipment still after pressing the button for 3 seconds around, the
icon would flash during this period, then it automatically enters
into the relative angle measurement mode. The
icon would
sustaining show on the screen. Short press ZERO button again to
exit the function.
6. Hold
If you need to move the device to read the display, press the HOLD
button to freeze the measurement. The
icon will display. Press
HOLD again to return to measuring mode.
7. Low battery indicator
Recommend to replace two new “AAA” batteries, when the low
Battery indicator “
” shows on the screen.
8. User’s calibration
a. Turn off the equipment. Put the equipment on a flat and smooth
solid surface. (see the following figure).
b. In the shutdown status, press and hold HOLD button first, then
press ON/OFF button, until the LCD display reads “CAL”.
c. Keep the equipment still for a period of time and then press the
HOLD button, display reads “CAL1”.
d. In the same location, rotate the equipment 180°(see the following
figure), then press the HOLD button
, display reads “CAL2”. After
the “CAL2” disappears, the calibration is completed and then the
LCD will show the current angle in high-accuracy-display.
NOTE:
● The calibration must be performed on a flat and smooth surface
with the tilt no more than 5°. If it exceeds 5°, display reads “Err”,
that indicates the user can’t proceed to do the calibration.
● During calibrating, the level also can not be beveled or moved.
● After completed calibration, the equipment automaticall
y replaces
from original factory data to consumer’s data, so it must be careful
to use this function.
DL1908 Digital Level
Display
Keyboard
Measuring Surface