Installation & Operation Manual

Installation
1.
Select the location where the EMS is to
be mounted. RF signals can be interrupted
by metal objects, including metal doors or
large mirrors. Ensure that these types of
objects are not in the way as it can interfere
with the proper operation of the EMS sensor.
2.
Place the mounting bracket in the position
you have selected. Secure the
bracket by using the two screws or adhesive tape provided.
1. Screws to hold bracket
2. Mounting bracket
3. Tab to release door sensor
4. Adhesive tape
3.
If you are using an external sensor on Zone 2 or Zone 3, it is recommended that you wire the sensor to the EMS before
mounting the EMS on the bracket. See the section on wiring external devices for detailed information.
4.
Open the house of the EMS and install the supplied battery. Use only a CR123A lithium battery.
5.
If you are using the integral door/window sensor, note the side of the EMS with the two raised lines, indicating where the
supplied magnet should be located. This is the same side as the small glass reed switch is fitted, visible when the case is open.
6. Mount the EMS using the tabs on the bracket. If necessary, use the supplied screw to secure EMS to the bracket.
7.
Mount the magnet a maximum of 20mm (3/4) from the EMS.
1. Screws to magnet or spacer
2. Adhesive tape
8.
For the magnet, use the screws provided. If necessary, use the spacers and adhesive tape provided.
9.
Open and close the door/window to ensure that there is no interference.
Enrolment
Auto Enrolment
If you are using the SOLO’s auto-enrolment feature, follow the instructions in your SOLO base station manual. Either
tamper switch or reed switch will serve to identify the EMS to the base-station.
IMPORTANT: Only the integral Zone 1 of the EMS can be auto-enrolled. External Zone 2 and Zone 3 must use
manually enrolment. See below.
Manual Enrolment
You can enrol the EMS manually using your service provider’s web portal. If you are enrolling zones 2 and 3, you
must use manual enrolment.
1. Record the 6-digit ESN number which is on a sticker on the side of the case and within the case
2. Use the ESN and the zone number to enrol the zone on the portal. All 3 zones use the same ESN but zones 2 and 3 are
differentiated but appending a colon and the zone number. For example, if the ESN was 12345A, you would enter the following
for each zone.