Installation Guide

4
PURPLE PURPLE
GREY GREY
FIXTURE WIRES DIMMER WIRES
Fig. 2
Fig. 3
Fig. 4
Fig. 1
INSTALLATION & ASSEMBLY:
1. Turn off the power at the circuit breaker box.
2. Remove the fixture from the packaging.
3. Rest the luminaire on the T-Bar of the ceiling
suspension system in the desired location (Fig. 1).
4. From above the ceiling, secure the Troffer to T-Bar by
bending built in hooks (#1) on all four corners of the
fixture (Fig. 2).
5. If local code requires, tie a wire to at least two of the
four hooks (#1) located near each corner of the
Troffer to a structural member of the ceiling (Fig. 2).
6. Remove the access plate (#2) located on the back of
fixture. Locate the black and white fixture supply
wires Quick Connector (Fig. 3).
7. Remove one knockout in the access plate (#2)
(Fig. 3).
8. Thread the power supply wires through the
knockout hole in the access plate (#2).
9. Remove the access plate located on back of fixture
(#3) and locate the purple (+) and grey (-) dimming
wires (Fig. 3).
10. Remove one knockout in the access plate (#3)
(Fig. 3)
11. Thread the dimming wires through the knockout
hole in the access plate (#3).
12. Connect the black supply wire and the white
supply wire to the quick connector. Connect the
supply ground wire to the fixture ground wire using
a wire nut.
13. Connect the purple and grey fixture wires to
corresponding wires of the wall 0-10V dimmer
(Fig. 4).