DOWNLIGHT
INSTALLATION INSTRUCTIONS
MODEL DRF6WHWH9105C
For use with Plaster Frame Model EVMP6HBMJ2W-I
Please read the instructions carefully and save these instructions, as you may
need them at a later date.
CAUTION
Turn power off at circuit breaker before beginning fixture installation to avoid
electrical shock.
GENERAL
All electrical connections must be in accordance with local and National
Electrical Code (N.E.C.) standards. If you are unfamiliar with proper electrical
wiring connections obtain the services of a qualified electrician.
Remove the fixture and the mounting package from the box and make sure that
no parts are missing by referencing the illustrations on the installation
instructions.
INSTALLATION INSTRUCTIONS
1. Mark the opening for the hole of the frame on the ceiling. Use a keyhole saw
to cut the hole out. [Fig. 1]
2. Pull the quick connector down from hole.
3. Remove a knockout to bring the supply wires into the wire box. [Fig. 2]
4. Connect the quick connector from the plaster frame to the quick connector
from the fixture. [Fig. 3]
5. Adjust the color temperature using the CCT switch. [Fig. 5]
6. Press the tension springs up and into the ceiling hole. [Fig. 4]
DIMMING
For a complete list of compatible dimmers, please look up the
item number listed on the cover of this instruction manual at
www.envirolite-LED.com.
QUESTIONS? CALL TOLL FREE
1-855-573-6156 or EMAIL
INFO@ENVIROLITE-LED.COM
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Beam Angle: 113°