ROUTINE MAINTENANCE:
At least once a year, run through the following procedures to ensure the system is clean and working 
properly. Check the burner to see if all the ports are clear and clean. Check the pilot to make sure it is not 
blocked by anything. The pilot ame should be blue with little or no yellow on the tips.
Warning: Clearances must be sufcient to allow access for maintenance and service
Warning:  Failure  to  position  the  parts  in  accordance  with  this  manual,  or  failure  to  use  only  parts 
specically approved with this appliance may result in property damage or personal injury.
The venting system must be periodically examined; it is recommended the examination is done by a 
qualied agency. 
CLEANING THE GLASS:
When the replace has cooled, remove the face of the replace along with the glass. See MAINTENANCE 
AND SERVICE - GLASS DOOR REMOVAL. Check the gasket material on the back of the glass, making sure that it 
is attached and intact. 
During a cold start up, condensation will sometimes form on the glass. This is a normal condition with all 
replaces. However, this condensation can allow dust and lint to cling to the glass surface. Initial paint 
curing of the appliance can leave a slight lm behind the glass, a temporary problem.  The glass will need 
cleaning about two weeks after installation. Use a mild glass cleaner and a soft cloth; abrasive 
cleaners will damage the glass and plated surfaces. Depending on the amount of use, the glass 
should require cleaning no more than two or three times a season. Do not clean the glass when it is 
hot.
CLEANING THE FIREBOX:
Remove the logs carefully, as they are very fragile. Gently remove all the embers and rock wool and 
place on a paper towel. Vacuum the bottom of the rebox thoroughly. Carefully clean any dust off the 
logs and remove any lint from the burner and pilot. At this time, inspect the burner pan for cracking or 
severe warping. If a problem is suspected, contact the dealer. Check the logs for deterioration or large 
amounts of soot; a small amount on the bottom side of the logs is normal. Replace the logs and embers 
as in the LOG SET AND EMBER INSTALLATION section. If new/more embers and rock wool are required, contact 
your nearest ENVIRO dealer. 
CHANGE BATTERY IN IGNITION MODULE:
If the  unit does  not spark  when lighting,  the battery  in the 
electronic ignition could need replacing.
Located on the left  hand rear corner of  the unit is a small 
rectangular  hole.  Located  here  is  the  electronic  ignition  module 
(see Figure 5).  Remove the battery cover, located on the left side 
of the module, and replace the AA battery.
Reinstall the battery cover and check for spark by depressing the 
pilot knob located on the control panel. 
Figure 5: Electronic Ignition Module 
Location.
9