Fire Pit User Manual
7
2. Start the pilot by pressing the gas control knob and turning it to PILOT.  
While holding the gas control knob in, press the piezo ignitor several 
times until the pilot light starts.  Hold  the gas control knob in  for 30 
seconds.  Check  that  the  pilot  has  fully  engulfed  the  thermocouple 
assembly (see Figure 3).
3. Start the main burner by turning the gas control knob to ON and then 
turn the rocker switch to ON. Check that all burner ports have ame.
4. Leak test all gas joints again.
Figure 3. Pilot Flame
Operating Instructions
PILOT LIGHT:
1. Turn off the gas to the replace.  If not recently done, remove the glass and let the unit air out 
for at least ve (5) minutes to clear out any gas. Turn on gas to the heater. Leak test all joints 
with soapy water. NEVER USE OPEN FLAME FOR LEAK TESTING. 
AIR SHUTTER:
The air shutter is controlled with the primary air adjustment rod located behind the gas valve shown in 
Figure 4.
The air shutter allows the amount of air coming into the replace to be adjusted in order to accommodate 
different climates and venting arrangements. Start the pilot and then the burner. Make sure the pilot 
ame is burning normally and none of the burner ports are plugged. Let the replace burn for roughly 
fteen (15) minutes and then examine the ames, compare the ames to Figure 61.
Gas valve
regulator
Gas valve
Primary air
adjustment rod
Figure 4: Gas Valve In Place on Unit.
The ideal ame will be blue at the base and light 
orange above. The ames should be of medium 
height.  If  the  ames  look  like  this,  no  venturi 
adjustment  is  needed.  If  the  ames  are  fairly 
short  and  mostly  blue,  the  replace  is  getting 
too much  air. Therefore, the  air shutter  should 
be  closed  slightly  until  the  correct  ames  are 
achieved.  Flames that are very orange, with tall, 
dark,  stringy  tips,  are  not  getting  enough  air. 
Open the venturi until the ames clean up. If the 
venturi is opened, or closed all the way, and the 
correct ames cannot  be attained, turn  off the 
gas and contact the dealer.
Warning:  Incorrect  venturi  adjustment  may  lead 
to  improper  combustion,  which  is  a  safety  hazard. 
Contact the dealer if there is any concern about the 
venturi adjustment.
Table 1: Venturi Information.
Natural Gas Propane
 Venturi Setting
1
/16” min.
3
/16” min.