Owner`s manual

9
Operating Instructions
For Your Safety, Read Safety Precautions And
Lighting Instructions Before Operating
NOTE: Check that all burner holes are lit.
TO TURN GAS FIREPLACE OFF:
Flip switch to OFF to turn off burners only
and turn the gas control knob to off to
extinguish the pilot ame. Keep the pilot
ame OFF when not in use. If the replace
is to be serviced, turn the gas shut off
valve to OFF (DO NOT FORCE IT) and
disconnect all electrical power sources.
See Figure 6 for control panel layout.
NOTE: When the unit is turned on for the rst time, it should be turned onto high, with the fan OFF
(if equipped), for the rst two to four hours. This will cure the paint, logs, gasket material, and other
products used in the manufacturing process. It is advised that a door or window be opened as the unit
will start to smoke, which can irritate some people. After the unit has gone through the rst burn, turn
the unit OFF, including the pilot, and let the unit get completely cold. Then remove the glass and clean
it with a good gas replace glass cleaner, available at your local Enviro dealer. See
MaIntenance anD
serVIce; Glass Door reMoVal and “MaIntenance anD serVIce; cleanInG the Glass.
Figure 6. Control Panel
Figure 7. Fan Control
buRneR Lighting:
A) Make sure the pilot is lit.
B) Turn gas control knob COUNTER CLOCKWISE to ON.
C) Flip the burner switch to ON.
D) Turn HI/LO knob to the desired ame height.
bLoweR sPeeD (oPtionaL):
The blower will come on only when the replace is up to temperature
(approximately 15 minutes). The speed of the fan can be changed by turning
the fan control knob. The blower will continue to operate automatically after the
unit has been shut off (approximately 25 minutes).To turn the blower off, turn
the knob COUNTER CLOCKWISE until it “clicks” off (Figure 7).
It is advisable not to operate the blower below
1
/3 speed as it puts a strain on
the windings of the blower and running the blower at lower speeds could also
cause premature fan failure.
noRmaL sounDs DuRing oPeRation:
Table 1: Normal Sounds
Component Sound & Reason
Q2 & Surround Panels Creaking when heating up or cooling down caused by thermal expansion
Burner Light pop or poof when turned off
Temperature Sensor Clinking when it senses to turn the blower on or off
Pilot Flame Quiet whisper while the pilot ame in on
Blower / Fan Air movement that increase and decreases with the speed of the blower
Gas Control Valve Dull click when turning on or off, this is the valve opening and closing
HI/LO
Control
Gas Control
Piezo Ignitor
Alternate Burner
Switch Location
DATE: 7/17/2014
BY
SHERWOOD INDUSTRIES LTD.
INTERNAL ASSEMBLY MANUAL
THIS DRAWING IS THE PROPERTY OF SHERWOOD INDUSTRIES LTD. AND MAY NOT BE COPIED, REPRODUCED, OR OTHERWISE DISCLOSED WITHOUT THE PRIOR APPROVAL OF SHERWOOD INDUSTRIES LTD.
1 of 2
SHEET:
Q2 (DV33) - R04
STOVE:
UPDATED: ----/--/--
BY
--
REVISION:
0.0
Fan Control
(Optional)
Shut Off Valve