Owner`s manual

Initial Installation
QUALIFIED INSTALLERS ONLY
eLectRicaL RequiRements:
Optional Fan Kit (50-2981): The fan will not operate if the appliance is cold. Once the unit is lit and the
fan is set to the desired level, the fan will automatically turn on upon reaching operating temperature.
The fan will automatically turn off after the appliance has cooled down.
The replace must be electrically connected and grounded in accordance with local codes or, in the
absence of local codes, with the current CSA C22.1 Canadian Electrical Code Part 1, Safety Standards For
Electrical Installations, or The National Electrical Code ANSI / NFPA 70 in the US..
CAUTION: When servicing controls, label all wires prior to disconnection. Wiring errors can cause
improper and dangerous operation. Verify proper operation after servicing.
If any of the original wire as supplied with the appliance must be replaced, it must be replaced with 18
AWG wire with a temperature rating of 105°C
Figure 33: Fan wiring diagram
29
(Building Wiring)