Specifications
7
Installation
clearanceS to combuStibleS:
12"
(30.5cm)
4" (10cm)
4" (10cm)
Side Wall
Back Wall
Adjacent Wall
These dimensions are minimum clearances but it is
recommended that you ensure sufficient room for
servicing, routine cleaning and maintenance.
Side wall to unit 12 inches (30.5 cm)
Back wall to unit 4 inches (10 cm)
Corner to unit 4 inches (10 cm)
Ceiling height 84 inches (213 cm)
Figure 3: Maxx-M Clearance to Combustibles.
thermoStat inStallation:
1. Install the wall thermostat (12 or 24 Volt rated) in
a location that is not to close too the unit but will
effectively heat the desired area.
2. Connect the Thermostat or Timer using a 2 x 18 gauge
wire from the unit to the thermostat.
If the heat in the room becomes to great, the high limit
switch may turn the stove off and the switch will have to
be manually reset. To reset the high limit switch, remove
the right cabinet side. The switch is found on the air
jacket.
Remove jumper
wire and install
thermostat wires here.
Figure 5: Thermostat wire placement.
hearth Shield inStallation:
1. Remove the right and left hand
cabinet sides. Partially back out
the two (2) T-20 Torx screws on
the back of the each panel and the
two (2) located on the front inside
edge below the louvers and ash
shelf. Pull the panel forward then
remove.
2. Slide the hearth shield into place.
3. Secure the shield to the unit with
two (2) screws on each side (see
Figure 4).
4. Re-install the side panels.
Figure 4: Maxx-M Hearth Shield Installation.