Specifications
17
Installation
Slider/damper Set-up:
This is used to regulate the airflow through the pellet stove. The slider damper should be set 
by a trained technician using magnehelic.
Exhaust Channel
Slider Damper
Exhaust Fan 
Housing
Set collars are 
installed on either 
side of the cabinet.
7
/16” (11mm)
 nuts
Rod
Knob
Figure 19: Slider/Damper Plate & Rod in Unit.
1. To install the optional slider damper 
rod  remove  the  left  cabinet  side 
panel. Partially back out the two (2) 
T-20 Torx screws on the back of the 
each panel and the two (2) located 
on  the  front  inside  edge  below  the 
louvers and ash shelf. Pull the panel 
forward then remove  and locate the 
slider damper plate. 
2. Install the 
7
/16” (11mm) nut onto the 
slider  damper  rod,  thread  it  all  the 
way onto the rod. 
3.  Slide  rod  through  the  hole  in  the 
slider  damper  plate  and  install  the 
7
/16”  (11mm)  clinching  nut  onto 
the  rod.  Leave  nut  a  little  loose  to 
help  it  line  up  when  the  cabinet  is 
re-installed. 
4. Re-install the cabinet side.
5. Mark the rod at either end of range 
in which the unit runs correctly and 
has  a  good  ame  pattern.  Pull  the 
rod out until the ame becomes a short, brisk flame, like a blowtorch; 
push the rod in a little and mark it. The next mark its the most important 
and is set with a magnehelic.
IMPORTANT: Taking a reading of vacuum pressure inside the firebox with 
a magnehelic gauge should be used to set the slider for best combustion. 
The slider damper should be set only on a hot stove (operating for thirty 
(30) minutes or more) by using a Magnahelic Pressure Gauge to measuring 
the  pressure  in  the  firebox. The  best  settings  are a  reading  of 
approximately 0.15 - 0.17 inches of water column (29.9 - 37.3 Pa) 
on the high fire setting. Some fuels may require higher or lower 
settings. The reading can be taken from the ⅛” (3 mm) hole located on 
the front of the unit below the ash shelf on the right hand side. 
6. Remove the cabinet side
7. Install a set collar ½” (12mm) in from the inner mark from step #5
Figure 20: Efficient Flame.
8. Re-install the cabinet side.
9. Install a set collar on the outside of the outer mark from step #5
10. Install the black knob on the end of the rod. Check slider damper for smooth operation. 