Specifications

Installation
clearanceS to combuStibleS:
12"
(30.5cm)
4" (10cm)
4" (10cm)
Side Wall
Back Wall
Adjacent Wall
These dimensions are minimum clearances but it is
recommended that you ensure sufficient room for
servicing, routine cleaning and maintenance.
Side wall to unit 12 inches (30.5 cm)
Back wall to unit 4 inches (10 cm)
Corner to unit 4 inches (10 cm)
Ceiling height 84 inches (213.4 cm)
Figure 4: Maxx Clearance to Combustibles.
thermoStat inStallation:
1. Install the wall thermostat in a location that is not to close too the unit but will effectively heat the
desired area.
2. Install a 12 or 24 Volt Thermostat using an 18 x 2
gauge wire from the unit to the thermostat.
If the unit has been placed in the HI / LOW mode, the unit
will be taken to a low or idle setting when the thermostat
is not calling for heat. When the thermostat calls for heat,
the unit will go to the setting that is displayed on the
control board Heat Indicator. If the heating load is not
great enough when the stove is on low, the high limit
switch will turn the stove off and the switch will have to
be manually reset. To reset the high limit switch, remove
the right cabinet side. The switch is found behind the
control panel. Avoid setting off the high limit switch.
Remove jumper
wire and install
thermostat wires here.
Figure 6: Thermostat wire placement.
hearth Shield inStallation:
1. Remove the right and left hand cabinet
sides. Partially back out the two (2) T-20
Torx screws on the back of the each panel
and the two (2) located on the front inside
edge below the louvers and ash shelf. Pull
the panel forward then remove.
2. Slide the hearth shield into place.
3. Secure the shield to the unit with two (2)
screws on each side (see Figure 4).
4. Re-install the side panels.
Figure 5: Maxx Hearth Shield Installation.
8