Owner`s manual
Installation
HoRizontaL eXHauSt tHRougH WaLL inStaLLation:
Vent installation: install vent at clearances specified by the vent manufacturer.
A chimney  connector  shall  not  pass  through  an  attic or  roof space,  closet or  similar  concealed  spaces, 
or a floor,  or  ceiling.  Where passage through a wall or partition of  combustible  construction is desired, 
the installation must conform to CAN/CSA-B365 Installation Code for Solid-Fuel-Burning Appliances and 
Equipment  and  with  all  local  regulations,  including  those  referring  to  regional  and  national.  Only  use 
venting of L or PL type or corn certified venting if corn will be burned as a fuel with an inside diameter of 4 
inches (100 mm). All joints in the exhaust venting system must be fastened with at least three (3) screws.
NOTE:
• It is recommended that horizontal through wall installations have a “T” and 3 to 5 feet (91 to 152 cm) 
of vertical pipe in the system to help naturally draft the unit in the event of extreme weather or a power 
outage.  This may also be required if a proper burn cannot be maintained, after the stove has been 
tested and the airflow set. This is due to the back pressure in the exhaust caused by airflow around 
the structure.
• Follow vent manufacturer guidelines for installation, clearance to combustibles, and sealing of venting. 
High temp Sealant must be used when connecting vent pipe to the unit’s starter pipe. Improper seals 
at the vent joints may cause combustion by-products to leak into the room where installed - seal as 
required by vent manufacturer.
1. Locate  the  center  of  the  exhaust  pipe  on  the  wall,  refer  to  pellet  vent  manufacturer  installation 
instructions for correct hole size and clearance to combustibles.
2. Install the wall thimble as per the instructions written on the thimble. Maintain an effective vapour 
barrier in accordance with local building codes.
3. Install a length of vent pipe into the wall thimble. Try not to have joints inside the thimble. The pipe 
should install easily into the thimble.
4. Connect  the  exhaust  vent  pipe  to  the  exhaust  pipe  on  the  stove.  Seal  the  connection  with  high 
temperature silicone.
5.  The  pipe  must  extend  at  least  12”  (30  cm)  away  from  the  building.  If  necessary,  bring  another 
length of pipe to the outside of the home to connect to the first section. Do not forget to place high 
temperature silicone around the pipe that passes through the thimble if required by vent manufacturer.
6. Install vent termination or 3-5’ of vertical pipe and a 90 degree elbow and vent termination.
23










