Owner`s manual

17
1. Lock fireplace damper in the open
position.
2. Install a positive flue connector at the
fireplace dampers.
3. Connect a clean-out tee or a 90° elbow to
the exhaust pipe.
4. Install flexible stainless steel liner or listed
pellet vent to the top of the chimney.
Recommended vent size for vertical
installation:
Under 15ft: 3” Vent
Over 15ft: 4” Vent

heaRth mount inStaLLation - fReeStanDing:
Figure 19: Hearth Mount - Side View.
Figure 20: Hearth Mount - Over View.
Floor
Protection
Combustible FloorMasonry Fireplace
Min 9"
Mantel
Minimum 8" (20 cm)
from top of stove
NOTE: Hopper lid will not open fully
with less than 13.5”.
Damper Removed
or Fastened Open
Clean-out tee
Fresh-air intake should
come from chimney. If
holes already exist
fresh-air intake can be
taken through back of
the fireplace or through
the ash dump.
Rain cap
Storm collar
Seal plate
(cover plate)
Existing masonry
flue
Vent pipe (single
wall stainless flex
pipe or solid PL
vent)
Fireplace damper
location
Clean out tee
Existing fireplace
Flexible vent
connector (use this
5' [1520 mm] section
of pipe to vent past
fireplace damper or
small shelf)