N IO AT TR ty I S ra n EG ar R /w T Y c om N A ir o . R R e nv A W SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER. PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE PELLET STOVE Empress-1 FS OWNER’S MANUAL Contact your building or fire officials about restrictions and installation inspection requirements in your area. PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET-BURNING ROOM HEATER.
Table of Contents Introduction........................................................................................3 Rating Label Location................................................................3 Pellet Quality............................................................................3 Important Safety Data...............................................................4 Safety Warnings And Recommendations.....................................4 Specifications.......................................
Introduction * This manual is designed for the home owner in conjunction with the technical manual. * Rating Label Location: The rating label is located on the back of the hopper. Pellet Quality: Pellet quality is important, please read the following: Your enviro pellet stove has been designed to burn wood pellets only. Do not use any other type of fuel, as this will void any warranties stated in this manual.
Introduction Important Safety Data: Please read this entire Owner’s Manual before installing or operating your ENVIRO Pellet Stove. Failure to follow these instructions may result in property damage, bodily injury or even death. Contact your local building or fire official to obtain a permit and any information on installation restrictions and inspection requirements for your area.
Introduction ASHES: Disposed ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should be on a non-combustible floor on the ground, well away from all combustible materials pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally dispensed, they should be retained in the closed container until all cinders have been thoroughly cooled. ELECTRICAL: The use of a surge protected power bar is recommended.
Specifications Dimensions: 153/4" (400mm) 153/8" (390mm) 253/4" (653mm) 247/16" (621mm) 273/8" (695mm) 243/16" (614mm) Figure 1: Empress Dimensions.
Operating Instructions Control Board Functions: 1. AUGER LIGHT: This green light will flash in conjunction with the auger pulse. 2. MODE LIGHT: Responsible for signaling the state of the control board. When the light is flashing the stove is in an automatic start mode or the thermostat has control of the unit. When the light is solid, the Heat Level Setting can be altered. 3. THERMOSTAT SWITCH: Used to set the unit’s controls to one of three mode settings; manual, high/low, or auto/off. 4.
Operating1 Instructions AUGER AUGER MANUAL MODE: MODE MODE 2 9 circuit board function is adjusted at the circuit board. All control of AUTO/OFF AUTO/OFF To START: Press the ON / OFF button. The stove will turn on. The HIGH/LOW HIGH/LOW 3 system light will flash. The Auger Light will flash with each pulse of the MANUAL MANUAL auger (the Auger Feed Rate is pre-programmed during start-up).
Operating Instructions Slider/Damper Set-Up: The Slider / Damper must be set at time of installation. A Qualified Service Technician or Installer must set the Slider Damper. This is used to regulate the airflow through the pellet stove. If the fire should happen to go out and the heat output indicator has been set on the lowest setting, the Slider Damper should be pushed in slightly, decreasing the air in the firebox.
Routine Cleaning and Maintenance The following list of components should be inspected and maintained routinely to ensure that the appliance is operating at its optimum and giving you excellent heat value: 2-3 Days / Weekly Burn Pot and Liner Ash Pan Inside Firebox Door Glass Heat exchanger tubes Ash pan and Door gaskets Door Latch Semi-annually or 2 Tons of Fuel Exhaust Vent Fresh air Intake Tube Blower Mechanisms Heat exchanger tubes Behind firebox liners All Hinges Post Season Clean-up TOOLS REQUIRED TO
Routine Cleaning and Maintenance ASH PAN (weekly) The ash pan is located under the ash shelf. To remove the ash pan, open the ash drawer by simply turning the latch and then pull the ash pan out towards the front. Dump the ashes into a metal container stored away from combustibles. Monitor the ash level every week. Remember that different pellet fuels will have different ash contents. Ash content is a good indication of fuel efficiency and quality.
Routine Cleaning and Maintenance EXHAUST VENT (season) This vent should be cleaned every year or after two (2) tons of pellets. We recommend contacting your dealer for professional cleaning. To clean the vent pipe, tap lightly on the pipe to dislodge any loose ash. Open the bottom of the “T” to dump the ash, then vacuum as much of the ash out of the vent pipe as possible. BLOWER MECHANISMS (season) Unplug the stove then open the right and left side panels to access the two blowers.
Warranty for Enviro Pellet Products Sherwood Industries Ltd. (“Sherwood”) hereby warrants, subject to the terms and conditions herein set forth, this product against defects in material and workmanship during the specified warranty period starting from the date of original purchase at retail. In the event of a defect of material or workmanship during the specified warranty period, Sherwood reserves the right to make repairs or to assess the replacement of a defective product at Sherwood’s factory.
Installation Data Sheet The following information must be recorded by the installer for warranty purposes and future reference.