7.OPERATING INSTRUCTIONS 
FOR YOUR SAFETY READ BEFORE OPERATING 
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION 
MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. 
A)  This appliance is equipped with a pilot, which must 
be lit by hand by following these instructions exactly. 
B)  BEFORE LIGHTING smell all around the appliance 
area for gas, and next to the floor because some 
gas is heavier than air and will settle on the floor. 
WHAT TO DO IF YOU SMELL GAS: 
•  Do not try to light any appliance. 
•  Do not touch any electrical switch; do not use 
any phone in your building. 
•  Immediately call your gas supplier from a 
neighbor’s phone. Follow the gas supplier’s 
instructions. 
•  If you cannot reach your gas supplier, call the 
fire department. 
C)  Use only your hand to push in or turn the gas 
control knob. Never use tools. If the knob will not 
push in or turn by hand, do not try to repair it . Call 
a qualified service technician. Force or attempted 
repair may result in a fire or explosion. 
D)  Do not use this appliance if any part has been 
under water. Immediately call a qualified service 
technician to inspect the appliance and to replace 
any part of the control system and any gas control 
which has been under water 
LIGHTING INSTRUCTIONS
1.  STOP! Read the safety information above. 
2.  Turn off all electrical power to the appliance. 
3.  Turn the gas control knob 
clockwise to the “off’ position. 
4. Open door.  Wait five (5) minutes to clear out any 
gas. Close door. If you smell gas including near 
the floor, STOP! Follow “B” in the above safety 
information. 
If you don’t smell gas go to next step. 
5.  Find the pilot located to the right between the front 
and rear burner. 
6.  Turn gas control knob  counter-
clockwise to “PILOT”. 
7.  Push the gas control knob in fully and hold. 
Immediately light the pilot by pushing the piezo 
spark igniter. Keep knob depressed for about 30 
seconds after pilot is lit.  Release knob. If pilot 
goes out, repeat steps 4 through 6. 
WARNING; The gas valve has a lockout device, 
which will not allow the pilot burner to be re-lit until 
the thermocouple, has cooled. 
If the knob does not pop up when released, stop 
and immediately call your service technician or gas 
supplier. 
 NOTE: Check to be sure the pilot flame engulfs the 
thermocouple and that the burners light 
completely. 
If the pilot will not 
stay lit after several 
tries, turn the gas 
control knob to 
“OFF" and call you 
service technician 
or gas supplier. 
Turn gas control knob counter-clockwise to  the 
“ON” position. 
Flip burner switch to “ON” then turn “HI / LO” knob 
to the desired setting. 
8.  Turn on all electrical power to the unit
TO TURN OFF GAS TO  APPLIANCE
1.  Turn the gas control knob 
clockwise to “OFF” DO NOT FORCE 
2.  Turn off all electrical power to the appliance if 
service is to be performed. 
3.  Flip burner switch to the off position. 
HI \ LO knob  Control knob 
9