- Sherwood Industries Ltd. Indoor Fireplace User Manual
5. VENTING 
WARNING; THIS APPLIANCE HAS BEEN DESIGNED TO OPERATE BY DRAWING COMBUSTION AIR 
AND DILUTION AIR FROM THE ROOM. IT IS ALSO DESIGNED TO DRAW ROOM AIR FOR PROPER HEAT 
CIRCULATION FROM THE SIDES OF THE UNIT. BLOCKING OR MODIFYING THE LOUVERS IN ANY WAY 
CAN CREATE HAZARDOUS SITUATIONS, EITHER THROUGH POOR VENTING OR BY OVERHEATING. IT 
IS IMPORTANT THAT THIS UNIT HAS SUFFICIENT AIR CIRCULATION FOR PROPER VENTING AND 
COMBUSTION. PROVISIONS MUST BE MADE FOR THE SUPPLY OF ADEQUATE COMBUSTION AND 
VENTILATION AIR. THESE OPENINGS MUST NOT BE BLOCKED. 
THE APPLIANCE MUST NOT BE CONNECTED TO A 
CHIMNEY FLUE SERVICING A SEPARATE SOLID FUEL 
BURNING APPLIANCE. 
VENTING FIREPLACE INSERTS 
The ENVIROGAS insert may be installed and vented into any 
solid fuel fireplace that has been installed in accordance with 
the National, Provincial/State and local building codes and has 
been constructed of non-combustible materials. 
An listed 4" chimney liner, seal plate, and rain cap must be 
installed, to ensure a tight seal, top performance, safety and 
efficiency. Carefully follow the chimney manufacturer’s 
instructions that accompany the liner kit. 
Measure the height of the chimney before hand and purchase 
the appropriate kit. Never attempt to over stretch a flexible 
liner to accommodate the height of the chimney. 
Install a seal plate to prevent leakage of room air through 
chimney. If the chimney is not sealed damage may occur to 
the appliance. 
Any flue damper must be removed or blocked permanently in 
the open position. 
The chimney must be clean, in good working order and 
constructed out of non-combustible materials. 
Make sure that all chimney clean outs are tightly fitting and will 
not permit air to leak into the chimney. 
Remove the vent collar plate from the top of the insert and 
connect it securely with at least 3 sheet metal screws and a 4" 
hose clamp. Check for any tears in the liner at this point. (See also Assembly and Installation Instructions section 
3.) 
Figure 7 
IMPORTANT: Replace the screw that holds the vent collar plate in it's approved position. 
The draft hood must be in the same pressure zone as the air inlet. 
To inspect draft from the front of the unit, open right side hinged flap. Locate 3/8” tube and check for draft using 
smoke or magnehelic gauge. A vacuum will indicate proper drafting.
7