- Sherwood Industries Ltd. Indoor Fireplace User Manual
These models have been tested and certified for use with SIMPSON DURAVENT DIRECT VENT TYPE "GS" PIPE FOR GAS 
STOVES. SECURITY VENTING SYSTEMS (SECURE VENT) Kits are available for vertical venting or horizontal venting. It is 
recommended that a bead of RTV High Temperature Silicone be applied to each outer vent joint and milpac to each inner joint 
before installation. 
This model has also been tested for horizontal venting installations when using SHERWOOD INDUSTRIES LTD. horizontal 
venting kit PART # EG 40-500 
SHERWOOD INDUSTRIES LTD PARTS: 
1  Horizontal direct vent termination cap 
1  Flue collar adapter 5” tall (4 T20 Torx) 
1 Wall thimble 
1  Inside finish trim collar 
1  5’ length of 4” double walled flex pipe 
2  24” sections 6 5/8’ straight pipe 
1  6 5/8” 90° elbow 
4 Spring spacers 
3  Decorative brass rings 
1  4oz tube RTV silicone 
1  4oz can charcoal gray spray paint 
20  9/16” tech screw 
8  1 1/2” wood screws 
1  Vinyl siding deflector
A MINIMUM VERTICAL LENGTH OF 24" TO THE FIRST 90 DEGREE ELBOW IS REQUIRED. WITH THIS MINIMUM 
VERTICAL RISE, HORIZONTAL RUNS OF FROM ONE TO FOUR FEET ARE PERMITTED TO REACH THE OUTSIDE VENT 
TERMINATION. 
BEFORE BEGINNING THE INSTALLATION TAKE CARE TO ENSURE AN APPROPRIATE OUTSIDE LOCATION FOR THE 
VENT TERMINATION CAN BE ACCOMMODATED. FOLLOW THE VENT LENGTH DIAGRAM PRECISELY. 
VENTING TERMINALS CANNOT BE RECESSED INTO A WALL OR SIDING. 
If extra elbows are being used, overall allowable length will be reduced by 3 ft. per additional elbow 
Simpson Duravent Parts 
Number   Description         Number   Description 
908B  6" Pipe Length, Black 
907B  9" Pipe Length, Black 
906 (B)  12" Pipe Length, (Black) 
904 (B)  24" Pipe Length, (Black) 
903 (B)  36" Pipe Length, (Black) 
902 (B)  48" Pipe Length, (Black) 
911 (B)  11" to 14-5/8" Pipe , Adjustable, Black 
945 (B)  45° Elbow, (Black) 
990 (B)  90° Elbow, (Black) 
940  Round Support / Wall Thimble Cover 
941  Cathedral Ceiling Support Box 
943  Flashing, 0/12 to 6/12 Roof Pitch 
943S  Flashing, 7/12 to 12/12 Roof Pitch 
953 Storm Collar 
963 Ceiling Firestop 
988 Wall Strap 
984  Horizontal Square Termination 
985  High Wind Horizontal Termination 
980 Vertical Termination 
991  High Wind Vertical Termination 
950  Vinyl Siding Standoff 
942 Wall Thimble 
971  Horizontal Termination Kit A 
Add suffix (B) for optional black parts as listed. 
PLANNING YOUR INSTALLATION 
There are two basic types of Direct Vent System installations. The two types of installations are: 
 Vertical Termination  Horizontal Termination 