- Sherwood Industries Ltd. Indoor Fireplace User Manual
 OPERATING INSTRUCTIONS 
FOR YOUR SAFETY READ BEFORE OPERATING 
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION 
MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. 
A) This appliance is equipped with a pilot, which must be lit by 
hand by following these instructions exactly. 
B) BEFORE LIGHTING smell all around the appliance area 
for gas, and next to the floor because some gas is heavier 
than air and will settle on the floor. 
WHAT TO DO IF YOU SMELL GAS: 
•  Do not try to light any appliance. 
•  Do not touch any electrical switch; do not use any 
phone in your building. 
•  Immediately call your gas supplier from a neighbor’s 
phone. Follow the gas supplier’s instructions. 
•  If you cannot reach your gas supplier, call the fire 
department. 
C)  Use only your hand to push in or turn the gas control 
knob. Never use tools. If the knob will not push in or turn 
by hand, do not try to repair it . Call a qualified service 
technician. Force or attempted repair may result in a fire 
or explosion. 
D)  Do not use this appliance if any part has been under 
water. Immediately call a qualified service technician to 
inspect the appliance and to replace any part of the 
control system and any gas control which has been under 
water 
LIGHTING INSTRUCTIONS
1.  STOP! Read the safety information above. 
2.  Turn off all electrical power to the 
appliance. 
3.  Turn the gas control knob clockwise  to 
the “off’ position. 
4. Open door.  Wait five (5) minutes to clear out any gas. 
Close door. If you smell gas including near the floor, 
STOP! Follow “B” in the above safety information. 
If you don’t smell gas go to next step. 
5.  Find the pilot located to the right between the front and 
rear burner. 
6.  Turn gas control knob counter-
clockwise to “PILOT”. 
7.  Push the gas control knob in fully and hold. Immediately 
light the pilot by pushing the piezo spark igniter. Keep 
knob depressed for about 30 seconds after pilot is lit. 
Release knob. If pilot goes out, repeat steps 4 through 6. 
WARNING  The gas valve has a lockout device, which 
will not allow the pilot burner to be re-lit until the 
thermocouple, has cooled. 
If the knob does not pop up when released, stop and 
immediately call your service technician or gas supplier. 
NOTE: Check to be sure the pilot flame engulfs the 
thermocouple and that the burners light completely. 
If the pilot will not 
stay lit after 
several tries, turn 
the gas control 
knob to “OFF" 
and call you 
service 
technician or gas 
supplier. 
8.  Turn gas control knob counter-clockwise 
to the “ON” position. 
Flip burner switch to “ON” then turn “HI / LO” knob to the 
desired setting. 
HI \ LO knob  Control knob
9. Turn 
on all electrical power to the unit
TO TURN OFF GAS TO  APPLIANCE
1.  Turn the gas control knob clockwise  to 
“OFF” DO NOT FORCE 
2.  Turn off all electrical power to the appliance if service is to 
be performed. 
3.  Flip burner switch to off. 
15