- Sherwood Industries Ltd. Indoor Fireplace User Manual
VENTING INTO CLASS “A” CHIMNEYS 
Simpson GS Dura 
vent cap 
Cap Adapter 
Class “a Chimney 
Roof Flashing 
4” flex liner inside 
Class “A” chimney 
Ceiling rafters 
Retro adapter 
GS Simpson Dura 
Vent pipe 4” x 6 5/8” 
This model is also certified and tested to vent into 
CLASS “A” wood. 
stove chimneys 
Place the freestanding direct vent appliance in the 
desired location. 
Using Simpson Dura Vent conversion kit #s 931-932-
933, depend on the ID diameter of the CLASS “A” 
chimney that this appliance is to be vented into. 
Place a bead of high temperature silicone or mil pac at 
each connection to ensure a tight seal. 
NOTE: A 4” flex liner must be used in the application. 
NOTE: Use Simpson Dura Vent from the top of the 
appliance until this vent reaches the CLASS “A” 
chimney. Install the retro adapter to the top section of 
GS direct vent pipe and install the flex liner to the retro 
adapter. 
Fully liner the CLASS “A” chimney with a minimum 4” 
flex liner to the top of the CLASS “A” chimney. 
Placing a bead of high temperature silicone to the 
Simpson Cap adapter and securely attach the flex liner 
to the adapter. 
Secure the cap adapter to the CLASS “A” chimney 
ensuring an air tight seal. 
Install the vertical termination cap. 
Light the unit and ensure proper operation. 
THE USE OF ANY EXISTING CHIMNEY AS AN AIR 
INTAKE IS NOT COVERED UNDER THE ANSI 
Z21.88-1999 CSA 2.33-M99 TEST METHODS AND 
THE RESULTING ITS/WHI PRODUCT 
CERTIFICATION. THE CODE AUTHORITY HAVING 
JURISDICTION MUST BE CONSULTED PRIOR TO 
PROCEEDING WITH THIS INSTALLATION METHOD. 
Mobile Home 
•  When the unit is installed in a Mobile Home it must be 
grounded to the steel chassis or connected to a 
grounding rod. 
•  In a Mobile Home installation the unit must be bolted 
securely to the floor using the holes provided. 
•  Manufactured (mobile) home installation must be in accordance 
with the Manufactured Home Construction and Safety Standard, 
UL 307B, Title 24 CFR, Part 3280 and/or The Standard for 
Manufactured Home Installations, ANSI A225.1/NFPA 501A 
13
Holes for unit hold 
down screws 