Install 2 spring spacers around the flex pipe. Slide the horizontal section of pipe 
over the flexible liner and install through the wall thimble, ensure that this 
portion of pipe slides onto the vent termination cap. Slide the inside finished 
collar over the horizontal section of pipe and secure to wall using the screws 
provided. Slide the 90° elbow over the flex pipe. Stretch the flex liner to a 
length long enough to ensure the flex liner can be easily connected to the flue 
outlet of the appliance. Install the remaining spring spacers over the flexible 
liner and install the vertical section of pipe.(DO NOT SLIP THESE SECTIONS 
OF PIPE TOGETHER, YOU WILL REQUIRE SOME MOVEMENT IN THESE 
PIPE SECTIONS IN ORDER TO SECURE THE FLEX PIPE TO THE FLUE 
OUTLET ON THE APPLIANCE.) 
12
Place a bead of high temperature silicone on the flue pipe and slide flex liner 
over collar, secure the flex liner with 3 sheet metal screws evenly spaced. 
Align all straight sections of pipe, slipping all joints together and installing 3 
sheet metal screws evenly spaced. 
A small can of touch up paint has been supplied with this kit. Lightly touch up 
any scratches that might have accord during the installation process. 
Install brass decorative rings around each joint making sure this decorative ring 
covers the sheet metal screws which secure each section of pipe together and 
secure to vent pipe in the slotted tab on the backside of the pipe so that the 
fastener would not be easily seen. 
Secure the horizontal section of pipe to the inside finished collar by installing a 
screw in the tab on the inside finished collar. (THIS WILL PREVENT THE PIPE FROM BEING DISCONNECTED AT THE 
VENT TERMINAL.) 
SPRING 
SPACERS
Light the appliance and ensure proper operation. 
WALL 
FRAMING 
HORIZONTAL WALL 
TERMINATION 
WALL THIMBLE
FIRE STOP 
DECORATIVE 
BRASS RINGS 
INSIDE 
FINISHED 
COLLAR 
EXHAUST
4” FLEX 
PIPE 
COMBUSTION 
AIR 
6 5/8” OUTER 
PIPE 