Specifications
26
Figure 35: P3 Heat Exchanger Tubes
HEAT EXCHANGER TUBES  (2-3 da
ys)
•  The heat exchanger tubes are located 
behind the Louver assembly. To access 
Heat Exchanger Scraper Rod, remove 
middle two louvers by tipping up and 
pulling out.
•  Pull out  the Scraper Rod  shown in 
Figure 35 in order to  remove any fly 
ash  that  may  have  collected  on  the 
heat exchanger tubes. This will allow 
for optimal heat transfer to convection 
air.
REMOVAL OF FIREBOX PANELS
•  Open  the  door,  remove  the  burn  pot 
and burn pot liner.
•  Lubricate  all  screws  with  penetrating 
oil.
•  Remove the four  screws that hold the 
side panels in place.
•  With the tip of a flat screwdriver, gently 
lift up the side panels and remove the 
side panels.
•  Pull the center panel out.
•  Vacuum thoroughly. 
•  Re-install  panel  by  inserting  center 
panel.
•  Place  the  side  panels  back  into  the 
firebox  locking  them  into  place  and 
re-install the two screws on each side.
•  Clean thoroughly.
Note: Screws that  secure left side 
panel  also  secure  hinge  bracket 
which holds cast door. Remove door 
before unscrewing.
•  To remove and rotate the side covers 
to open them.
•  Vacuum out all three 3 chambers.
•  Close  all  the  clean-out  covers  and 
tighten the screws.
Routine Cleaning and Maintenance
Scaper
Rod
Remove
Figure 36: P3 Firebox Panels