Specifications
21
Operating Instructions
CONTROL BOARD FUNCTIONS:
1. POWER BUTTON: This is the green button with the power symbol, it is used
to turn the unit on and off. When the power is on and the blue LED beside the
button will be illuminated. The LED will flash during the start-up cycle. Once start-
up cycle is complete the power LED will stay on.
2. AUTO BUTTON: Located below the Power button, when pressed this activates
Auto or “Comfort” mode. LED beside button will be illuminated when active.
3. THERMOSTAT BUTTON: Located below the Auto Button. This is for external
thermostat control. LED beside button will be illuminated when active.
4. ARROW BUTTON: The Arrow Buttons are used to adjust heat level and trim
settings.
START-UP: When the unit is turned on it will go into a start-up cycle while trying
to light a fire. During start-up you have no control over the settings. The Power
LED will flash until start-up is complete. You can adjust heat levels or toggle the
different modes during start-up but these adjustments will not come into affect
until the start-up cycle is complete.
MANUAL MODE: Once the start-up cycle is completed you will be in either Manual
mode or Auto mode. When in Manual mode the Power LED is illuminated and
AUTO LED is not. Use the Arrow buttons to adjust heat level from L1-L5.
AUTO MODE: Press the Auto button to activate Auto or “Comfort” mode. When
activated the Power and Auto LED’s will be illuminated. Use the Arrow buttons
to adjust from C1-C9. Each setting corresponds to a different temperature set
point. The stove will automatically adjust to hold this temperature. As the room
temperature gets close to the set point the fire will decrease in size. If room
temperature is above the set point for a certain amount of time the stove will shut
down and go into Suspend mode.
SUSPEND MODE: Once a stove has gone into Suspend mode the fire will go out.
This means the room has heated up beyond the Auto set point. Once temperature in the room drops below the
Auto set point the stove start back up and run until the room gets to hot once again. When in suspend mode
the Auto LED will flash.
THERMOSTAT MODE: This can only be used in Manual mode, and is for external thermostat control. A external
thermostat can be wiring to the main control board. When activated the LED beside the Thermostat Button will
be illuminated.
FEED/COMBUSTION TRIM: To adjust the Feed Trim you must be in Manual mode heat level 1. Press the
hidden button located under the down arrow. The Display will then change from P (Program) to A (Auger) to C
(Combustion) with a two second delay between changes. When the display shows an A use the arrows to adjust
the feed trim. To adjust the combustion fan trim wait until the display shows C then use the arrows to adjust.
Auto
Figure 28: Circuit Board
Control Panel Decal.
AUTOMATIC SAFETY FEATURES OF YOUR PELLET STOVE:
A. The stove will shut off when the fire goes out and the exhaust temperature drops below 120°F (49°C).
B. The stove has a high temperature safety switch. If the temperature on the hopper reaches 200°F
(93°C), the auger will automatically stop and the stove will shut down. The LED display will show an
E3 error cod, see Troubleshooting section. If this happens, call your local dealer to reset the 200°F
(93°C) high limit switch. ALSO FIND THE REASONS WHY THE UNIT OVERHEATED.
C) The unit is equipped with a vacuum switch to monitor the venting; if it becomes blocked the vacuum
switch will turn off the auger and there will be an E2 error code on Th eLED Display.