Specifications

19
Roof Sheathing
Rain Cap
Roof Flashing
Roof Rafters
Ceiling Joists
Vent Pipe
Exterior Wall
Sheathing
Outside Vent
Termination
Installation
TYPICAL THROUGH WALL WITH EXTERIOR BLOWER KIT INSTALLATION - VERTICAL TERMINATION:
Figure 25: Through Wall Installation with Exterior Blower Kit;
Vertical Termination.
THERMOSTAT INSTALLATION:
1. Install the wall thermostat in a location that is not to close too the unit but will effectively heat the
desired area.
2. The Right Cabinet Side will need to be removed to
access the Control Board. Once the side has been
removed you can remove three screws securing the
Control Board Cover.
3. Now that the board can be accessed, wire the
Thermostat using to the Control Board using an
18 gauge, 2 connector wire from the unit to the
thermostat.
Figure 26: Thermostat wire placement.
Follow the previous pages for through wall
instal
lations. Ensure that vent pipe is properly
secured to wall using wall straps. Maintain clearances
to combustibles on vent pipe as well as unit.