Specifications
17
Installation
EXTERIOR MOUNTED EXHAUST BLOWER (20-070):
1. Remove the left hand cabinet side by removing the six mounting
scr
ews down the front. Loosen the three screws, slide the
cabinet side forward and remove panel.
2. Loosen the six screws that hold the back grill in place. Lift the
back grill off the screws.
3. Disconnect the Exhaust blower wires from the wire harness.
Remove the exhaust blower motor from the housing; six screws.
Cover hole in housing with cover plate provided (see Figure 21).
4. Remove the cover from the exterior exhaust blower housing
box.
5. Install the exhaust blower housing box into the pipe placed
through the wall thimble, seal with high temperature silicone.
Fasten the box to the wall with (4) four screws, seal edges of
box to wall with clear silicone.
6. Drill a hole through the wall thimble plate for the electrical wires.
Pass the armored cable through the wall thimble. Use the strain
relief provided. Do not pass cable through vent hole.
7. Install the Exhaust Blower motor into the external exhaust
blower housing box. Make the electrical connections to the wire
harness and exhaust blower.
8. Replace the cover on the exterior Exhaust Box and the back grill
of the stove and ensure the screws are tightened down.
9. Install vertical pipe as instructed in appropriate section.
The P3 can be equipped with an externally mounted exhaust blower.
This optional kit includes all components necessary to install the exhaust
blower on any vertical wall surface.
Choose a location for your stove that meets the requirements stated in
your manual and allows installation with the least amount of interference
with house framing, plumbing, wiring, etc. Make sure unit is unpluged.
Included in the Exterior Mounted Exhaust Blower Kit are:
1 - Exhaust blower housing box.
1 - Blower cover plate.
1 - Hardware bag
Figure 20: Exterior Blower Kit.
Figure 21: Exterior Blower Kit.
Figure 22: Exterior Blower Kit section view
.