Specifications

16
Installation
HEARTH MOUNT INSTALLATION:
Figure 19: Freestanding hearth mount installation overview.
Refer to Figures 18 and 19.
1. Install the hearth pad.
2. Lock the fireplace damper in the open
position.
3. Install a positive flue connector at the
fireplace dampers or seal the chimney at
the top.
4. Connect a tee to the exhaust pipe.
5. Install flexible stainless steel liner or listed
pellet vent to the top of the chimney.
Figure 18: Freestanding hearth mount installation.
Min 6" (150 mm)
Optional Hearth
or Other
Floor Protection
Combustible FloorMasonry Fireplace
10" (25.4 cm) Mantel
Minimum 8" (20 cm)
from top of stove
Damper Removed
or Fastened Open
Clean-out tee
Flue
Connector
Rain cap
Storm collar
Seal plate (cover plate)
Existing masonry flue
Vent pipe (single wall
stainless flex pipe or
solid PL vent)
Fireplace damper
location
Clean out tee
Existing fireplace
Flexible vent connector
(use this 5 foot [152cm]
section of pipe to vent
past fireplace damper or
small shelf)