Operating instructions

13
Installation
cleaRanceS to combuStibleS - fReeStanDing:
When installing this unit on a combustible floor (for example linoleum, hardwood flooring) a non-
combustible hearth pad must be under the unit. The pad must extend at least the width of the appliance
[22” (558 mm)] and at least the depth of the appliance plus 6” (153 mm) in front of the appliance [29
¾” (756 mm)].
Side wall to unit - 6 inches (15 cm)
Back wall to unit - 1 inches (2.5 cm)
Corner to unit - 1 inches (2.5 cm)
Door front to edge of floor protection
- 6 inches (15 cm)
30"
(76 cm)
48"
(122 cm)
36"
(91cm)
6"
(152 mm)
1"
(25 mm)
1"
(25 mm)
6"
(152 mm)
Back Wall
Side Wall
Adjacent Wall
Floor Protection
Figure 9: EF3 Freestanding Clearance to Combustibles.
Minimum Alcove width - 36 inches (91 cm)
Minimum Alcove height - 48 inches (122 cm)
Maximum Alcove depth - 30 inches (76 cm)
Figure 10: EF3 Freestanding Minimum Alcove Size.
cleaRanceS to combuStibleS - fiRePlace inSeRt:
10" (25.4 cm) Mantel
8"
(20.3 cm)
8"
(20.3 cm)
Side Wall
Floor Protection; Minimum 6" (15 cm) in front of door
Figure 11: EF3 Fireplace Insert Clearance to Combustibles.
Refer to Figure 11.
Side wall to unit - 8 inches (20.3 cm)
Mantel projection - 10 inches (25.4 cm)
Mantel to top of unit - 8 inches (20.3 cm)
Top facing to unit - 8 inches (20.3 cm)
Side facing to unit - 6 inches (15.2 cm)
Floor protection - 6 inches (15.2 cm)
on either side and to the front must be
protected by non-combustible material.
These dimensions are minimum clearances but it is
recommended that you ensure sufficient room for
servicing, routine cleaning and maintenance.