Initial Installation
QUALIFIED INSTALLERS ONLY
VENTING INTO A CLASS ‘A’ CHIMNEY:
This model is also certied and tested to vent into CLASS A wood
stove chimneys.
Place the freestanding direct vent appliance in the desired location.
Use a conversion kit from Simpson Duravent (931, 932, or 933), or
Security Chimney (SV4CCK1, SV4CCK2, or SV4CCK1). Which kit is used
will depending on the inner diameter of the CLASS Achimney that this
appliance is to be vented into.
Place a bead of high temperature silicone or Mil-Pac at each connection
to ensure a tight seal.
NOTE: An approved 4” (10 cm) diameter ex liner must be used in the
application.
NOTE: Use Simpson Dura Vent from the top of the appliance until this
vent reaches the CLASS Achimney. Install the retro adapter to the
top section of GS direct vent pipe and install the ex liner to the retro
adapter.
Fully line the CLASS ‘Achimney with a minimum 4” (10 cm) ex liner
to the top of the CLASS ‘A’ chimney.
Place a bead of high temperature silicone to the Simpson Cap adapter
and securely attach the ex liner to the adapter.
Secure the cap adapter to the CLASS Achimney ensuring an airtight
seal.
Install the vertical termination cap.
Light the unit and ensure proper operation.
THE USE OF ANY EXISTING CHIMNEY AS AN AIR INTAKE IS NOT
COVERED UNDER THE ANSI Z21.88-2002 CSA 2.33a-2002 TEST
METHODS AND THE RESULTING ITS/WH PRODUCT CERTIFICATION.
THE CODE AUTHORITY HAVING JURISDICTION MUST BE CONSULTED
PRIOR TO PROCEEDING WITH THIS INSTALLATION METHOD.
Simpson GS
Dura Vent Cap
Cap Adapter
Class A
Chimney
Roof Flashing
4” (10cm) Flex Liner
Inside Class A Chimney
Ceiling Rafters
GS Simpson Dura
Vent Pipe 4” x 6
5
/
8
Figure 24: Assembly of Venting into a
Class ‘A’ Chimney.
MOBILE HOME INSTALLATION:
When the unit is installed in a Mobile Home it must
be grounded to the steel chassis or connected to a
grounding rod.
• In a Mobile Home installation the unit must be bolted
securely to the oor using the holes provided.
Manufactured (mobile) home installation must be in
accordance with the Manufactured Home Construction
and Safety Standard, UL 307B, Title 24 CFR, Part
3280 and/or The Standard for Manufactured Home
Installations, ANSI A225.1/NFPA 501A
Holes for screws to
hold down the unit.