Operating instructions

22
Installation
model 1700-c Brick placement & tuBe locations:
COMPLETE THE STOVE AND SMOKE PIPE INSTALLATION BEFORE PLACING THESE BRICKS.
TOTAL BRICKS:
16 - Full size bricks 9” long x 4.5” wide x 1.25” thick
(22.9 cm long x 11.4 cm wide x 3.2 cm thick)
2 - Partial bricks 9” long x 3” wide x 1.25” thick
(22.9 cm long x 7.6 cm wide 3.2 cm thick)
Removing Air Tube: If a secondary air tube needs to be removed, place a screwdriver (any style except
at head) into one of the air holes and tap it with a hammer/mallet to the left until the right end of the
tube is freed. To installation a secondary air tube reverse the above instructions.
IMPORTANT: All secondary air tubes must be in place for proper operation.
F
u
l
l
S
i
z
e
B
r
i
c
k
P
a
r
t
i
a
l
B
r
i
c
k
Tube A
Tube C
Tube B
F
u
l
l
S
i
ze
B
r
i
c
k
F
u
l
l
S
i
z
e
B
r
i
c
k
Figure 22: Brick Placement for 1700-C shown with Secondary Air Channel
and Tubes.
1. Place the four (4) full size
bricks along each side of
the rebox and one (1) full
size brick on either side of
the back of the rebox.
2. To place the oor bricks, lay
the two (2) partial bricks
along the back of the oor.
Then lay six (6) full size
bricks in the front. The
spaces between the bricks
will soon ll with ashes.
When replacing bricks,
use only pumas type re
bricks.