Operating instructions

21
Installation
model 1200-c Brick placement & tuBe locations:
COMPLETE THE STOVE AND SMOKE PIPE INSTALLATION BEFORE PLACING THESE BRICKS.
TOTAL BRICKS:
12 - Full size bricks 9” long x 4.5” wide x 1.25” thick
(22.9 cm long x 11.4 cm wide x 3.2 cm thick)
2 - Partial bricks 9” long x 3” wide x 1.25” thick
(22.9 cm long x 7.6 cm wide 3.2 cm thick)
Removing Air Tube: If a secondary air tube needs to be removed, place a screwdriver (any style except
at head) into one of the air holes and tap it with a hammer/mallet to the left until the right end of the
tube is freed. To installation a secondary air tube reverse the above instructions.
IMPORTANT: All secondary air tubes must be in place for proper operation.
P
a
r
t
i
a
l
B
r
i
c
k
F
u
l
l
S
i
z
e
B
r
i
c
k
Tube A
Tube E
Tube D
F
u
l
l
S
i
z
e
B
r
i
c
k
Figure 21: Brick Placement for 1200-C shown with Secondary Air
Channel and Tubes.
1. Place the three (3) full size
bricks along each side of the
rebox and one (1) full size
brick on either side of the back
of the rebox.
2. To place the oor bricks, lay
the two (2) partial bricks along
the back of the oor. Then lay
four (4) full size bricks in the
front. The spaces between the
bricks will soon ll with ashes.
When replacing bricks, use
only pumas type re bricks.