Operating instructions
speciFications:
Table 1: 1200-C & 1700-C General Information.
Model 1200 Insert 1700 Insert
Width x Depth
27¾” x 22”
(705 mm x 559 mm)
27¾” x 26.5”
(705 mm x 673 mm)
Height of body 19
1
/16” (484 mm) or 19
9
/16” (497 mm)
Fire box size
(depth x width x height)
16.1” x 18.25” x 11.15”
(409 mm x 464 mm x 283 mm)
20.65” x 18.25” x 11.95”
(525 mm x 464 mm x 304 mm)
Capacity
1.85 feet
3
(0.0526 meter
3
)
2.5 feet
3
(0.0708 meter
3
)
* Approximate heating area
2200 feet
2
(205 meter
2
)
3000 feet
2
(280 meter
2
)
**E.P.A. output rating
11,479 to 34,196 BTU/hour
(3,361 to 10,013 watt)
9,425 to 31,780 BTU/hour
(2,760 to 9,306 watt)
*Duration on low burn 6 -10 hours 8 - 12 hours
Weight with packaging 335 lb (151.95 Kg) 390 lb (176.90 Kg)
E.P.A. Emissions
3.3 grams/hour
(0.116 oz/hour)
4.48 grams/hour
(0.158 oz/hour)
Surround Panel
Standard (width x height) 49.25” x 31.25” (1251 mm x 794 mm)
Rating Label Location Side of Unit; Behind Right Shroud
10
Specications
air control:
The primary air is controlled by the rod located on the right side of the unit. To increase your air, pull the
rod out and to decrease, push the rod in. All the units have a secondary air that ows through the tubes
at the top of the rebox, just below the bafes.
Pull this control all the way out when rst starting the
stove. Once the re has been established you may
adjust this control to set the burn rate of the re. For
optimal efciency, use a low to medium setting. If this
damper is closed at rst start-up, the re will burn very
slowly and could soot the appliance.
When shutting down the stove, fully open the air
control. This allows the chimney temperatures to
remain as high as possible for as long as possible. Cold
chimney temperatures create creosote.
Figure 3: Air Control Rod.