FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” WOOD 
STOVE, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION:
● Please read this entire manual before you install and use your new woodstove. Failure to 
follow instructions may result in property damage, bodily injury or even death. Be aware 
that local Codes and Regulations may override some items in this manual. Check with your 
local inspector.
● If this appliance is not properly installed, operated and maintained, a serious house re could result. 
Makeshift materials during installation could also result in a serious house re.
● HOT WHILE IN OPERATION. KEEP CHILDREN, CLOTHING,  AND  FURNITURE  AWAY.  CONTACT  MAY 
CAUSE SKIN BURNS.
● Operate only with the door and ash plug tightly closed and burn wood directly on the stove hearth. Do 
not operate if the door glass is broken or a gasket is missing or damaged. Do not alter the combustion 
air  control  valves.  Dangerous overring could  occur  which  could  ignite  creosote  in the  chimney  or 
cause a house re.
● At least 12 square inches (77.4 cm
2
) of fresh outside air should be admitted into the room or directly 
to the stove through a 4 inch (10.16 cm) diameter pipe. For the stove to operate combustion-air must 
be supplied through either the bottom or the back of the unit.
● Do not burn coal or charcoal as there is danger of carbon monoxide being produced. DO NOT USE 
CHEMICALS OR FLUIDS TO START THE FIRE. DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS SUCH 
AS GASOLINE, GREASE, NAPHTHA OR ENGINE OIL. Never let the stove become hot enough to get any 
part red or glowing red.
● Burning wet, unseasoned wood could cause excessive creosote accumulation in the ue pipe. When 
ignited, it could cause a chimney re that could result in a serious house re.
● Do not use grates, andirons or any other methods to support or raise the re up off the hearth of the 
appliance.
● This appliance is tested to ULC-S627-00 Standard for Space Heaters for Use with Solid Fuel & UL 1482 
-10 Standard for Safety for Solid-Fuel Type Room Heaters. 
● In Canada the existing chimney must be lined to the termination for all masonry installs. 
● A chimney connector shall not pass through an attic or roof space, closet or similar concealed space, 
or a oor, or ceiling. 
● Where passage through a wall, or partition of combustible construction is desired, the installation shall 
conform to CAN/CSA-B365, Installation Code for Solid-Fuel-Burning Appliances and Equipment. 
● DO NOT CONNECT TO OR USE IN CONJUNCTION WITH ANY AIR DISTRIBUTION DUCTWORK UNLESS 
SPECIFICALLY APPROVED FOR SUCH INSTALLATIONS.
● In the event of component failure, only manufacturer specied replacement parts may be used.
● DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
● Ensure that the ash plug is installed over the ash dump hole.
● Do not open the ash pan compartment while the unit is burning.  Allow unit to fully cool before touching 
the ash pan latch.