Figure 19: Freestanding installation into mobile home.
Manufactured (Mobile) home installation must be in accordance with the Manufactured Home Construction 
and Safety Standard, UL 307B, Title 24 CFR, Part 3280 and/or The Standard for Manufactured Home 
Installations, ANSI A225.1/NFPA 501A.
WARNING: DO NOT INSTALL IN SLEEPING ROOM.
Chimney  must  be  removable  to  allow  for 
transportation of the mobile home.
CAUTION:  THE  STRUCTURAL  INTEGRITY 
OF  THE  MOBILE  HOME  FLOOR,  WALL,  AND 
CEILING/ROOF MUST BE MAINTAINED.
OUTSIDE AIR :
Connection from the stoves air intake to the outside 
is  mandatory,  (MOBILE  HOMES  ONLY)  either 
through a hole in the wall not higher than the stoves 
bottom  or  through  a  hole  in  the  oor,  using  the 
fresh air adaptor. Avoid cutting any oor joists, wall 
studs, electrical wiring or plumbing. Seal around the 
outside  air  pipe  with  insulation  to  prevent  drafts. 
Also install a ¼” mesh rodent or pest screen in the 
end of fresh-air pipe. Fresh-air connection must be 
of a non-combustible material, example: 4” (10.16 
cm) exible aluminum single wall pipe.
Fresh  air  could  also  be  supplied  from  a  vented 
crawlspace.
The  legs  must  be  rmly  bolted  to  the  oor using 
four ¼” bolts. Be sure to replace any insulation or 
panels removed when fastening the bottom nuts.
If room air starvation occurs because the air intake 
is blocked with ice, leaves etc., or because the stove 
door was left open, or due to a strong exhaust fan 
operating, dangerous fumes  could  be  sucked into 
the room.
IN  SOME  AREAS  IT  MAY  BE  REQUIRED  TO 
ELECTRICALLY GROUND THE STOVE TO THE STEEL 
CHASSIS OF THE MOBILE HOME.
When this unit is installed in a Mobile Home it must 
be grounded to the steel chassis or connected to a 
grounding rod.
Installation
At least 
3 feet (914 mm)
Hearthpad
Floor
Woodstove
Outside air connection
through wall or floor
Double wall pipe
Ceiling support
Ceiling
Spark arrestor cap
Roof flashing
Roof
Radiation Shield
Insulated 
chimney
Bolt stove to floor