Operating instructions
23
Installation
instAllAtion oF A listed, FACtorY Built CHimneY:
This is a generic set of instructions; always follow the chimney manufacturer’s instructions 
explicitly. Also refer to “reCommended HeigHts For Flue pipe”.
1.  Set  non  combustible  oor  protector  and  stove  in  location  in  accordance  with  the  “
CLearanCes  to 
Roof
Ridge
2 ft (0.6 m)
Minimum
3 ft (0.9 m)
Minimum
Within10 ft (3 m)
CombustibLes”.
2.  Mark the position  for the  ceiling hole by 
suspending  a  plumb  bob  from  the  ceiling 
over the exact center of your stove ue and 
mark  a  spot  on  the  ceiling  to  indicate  the 
center of the chimney. 
3.  Move  this location, if necessary, to avoid 
oor  joists,  ceiling  rafters,  electrical  wiring 
and plumbing while still maintaining required 
clearances.  If  oor  joists  or  ceiling  rafters 
must be cut they must be made structurally 
sound  again.  Install  chimney  according 
to  chimney  manufacturers  instructions.  A 
chimney  connector  cannot  pass  through 
an  attic  or  roof  space,  closet  or  similar 
concealed  space,  or  a  oor,  ceiling,  wall 
or  partition  of  combustible  construction. 
In Canada, if passage through a wall or 
partition  of  combustible  construction  is 
desired,  the  installation  shall  conform  to 
CAN/CSA-B365  Installation  Code  for  Solid-
Fuel Burning Appliances and Equipment and 
NFPA 211 Standard for Chimneys, Fireplaces, 
Vents, and Solid Fuel-Burning Appliances.
4.  Mark the hole for the outside air kit.
5.  Move the stove out of the way.
6.  Cut a pilot hole in the ceiling.
7.  Cut  a  hole  for  the  ceiling  penetration 
components  and  frame  in  the  sides  of  the 
hole in both the ceiling and roof. Check, and 
follow  chimney  manufacturer’s  instructions 
for all of these steps.
8.  Install the support box and chimney through 
the  roof.  Install  the  slip  section  for  the 
chimney connector.
9.  Slip the  roof  ashing over the  chimney  and 
secure to the roof, being careful to keep the 
pipe  centered  in  the  opening.  To  meet  the 
code,  the  chimney  must  extend  above  the 
roof penetration at least 3 feet (91.4 cm), and 
in any area within 10 feet (304.8 cm) of the 
Figure 14: Standard Vertical Installation.
Figure 13: Roof Clearances.
Hearthpad
Floor
Woodstove
Outside air connection
through wall or floor
Ceiling support
Ceiling
Radiation shield
Insulated chimney
Rain cap/
Spark arrestor cap
Roof flashing
Roof
Attic
radiation shield
Minimum air space in
accordance with 
chimney manufacturer.
Chimney
connector
Storm Collar