Table 13: Examples of Corner Installation Using Clearances From Tables 9 &10 (refer to Figures 23 & 24).
(K) Front of
Hearth Pad to
Corner
(L) Adjacent
Wall
(M) Edge of
Hearth Pad to
Adjacent Wall
(N) Width at
back of Hearth
Pad
(O) Back Corner
Removed -
Adjacent
(P) Back Corner
Removed -
Diagonal
Single
Wall Pipe
1200 Canada 61⅜”
(1558mm)
57⅝”
(1465mm)
29⅛”
(738mm)
30⅝”
(779mm)
4⅞”
(124mm)
7⅛”
(182mm)
USA 59⅜”
(1507mm)
54⅞”
(1393mm)
29⅛”
(738mm)
34⅝”
(881mm)
⅞”
(23mm)
1¼”
(32mm)
1700 Canada 67¼”
(1708mm)
61⅞”
(1571mm)
33¼”
(844mm)
33½”
(851mm)
3½”
(88mm)
4⅞”
(125mm)
USA 65¼”
(1657mm)
59”
(1499mm)
33¼”
(844mm)
36½”
(926mm)
0”
(0mm)
0”
(0mm)
Double
Wall Pipe
1200 Canada 59⅞”
(1522mm)
56⅝”
(1439mm)
28⅛”
(713mm)
27⅞”
(707mm)
6¼”
(160mm)
8⅞”
(227mm)
USA 57⅞”
(1471mm)
53⅞”
(1368mm)
28⅛”
(713mm)
31⅞”
(809mm)
2¼”
(59mm)
3¼”
(83mm)
1700 Canada 65⅛”
(1654mm)
60⅜”
(1533mm)
31¾”
(806mm)
29¼”
(743mm)
5⅝”
(142mm)
7⅞”
(201mm)
USA 63⅛”
(1603mm)
57½”
(1461mm)
31¾”
(806mm)
33¼”
(845mm)
1⅝”
(41mm)
2¼”
(59mm)