Operating instructions
Non combustible oor protection must be under the chimney connector and 2 inches (50.8 mm) beyond
each side.
18
Installation
HeArtH proteCtion exAmples:
Table 11: Examples of Hearth Pad Sizing Using Clearances From Tables 9 &10 (refer to Figures 22 & 23).
Canada USA
1200 1700 1200 1700
(A) Minimum Width 40½” (1028mm) 36½” (926mm)
(B) Minimum Depth
46”
(1168mm)
50½”
(1283mm)
42”
(1067mm)
46½”
(1181mm)
OPTIONAL - Corner removal
(C) Maximum Front Corners -
Adjacent
8¾” (314mm) 6¾” (171mm)
(D) Maximum Back Corners -
Adjacent
6¼” (160mm) 5⅛” (130mm)
(E) Maximum Front Corners -
Diagonal
12⅜” (314mm) 9½” (242mm)
(F) Maximum Back Corners -
Diagonal
8⅞” (227mm) 7¼” (185mm)
(G) Minimum Width remaining
without corners - Front
23” (583mm) 23” (583mm)
(H) Minimum Width remaining
without corners - Back
27⅞” (707mm) 26⅛” (665mm)
Table 12: Examples of Parallel Installation Using Clearances From Tables 9 &10 (refer to Figure 22).
Model Country
(I) Far Edge of Hearth Pad
to Side Wall - Minimum
(J) Front of Hearth Pad to
Back Wall - Minimum
Single Wall Pipe
1200
Canada 45½” (1156mm) 49¼” (1252mm)
USA 43½” (1104mm) 47¼” (1201mm)
1700
Canada 52½” (1333mm) 54¾” (1391mm)
USA 50½” (1283mm) 52¾” (1340mm)
Double Wall Pipe
1200
Canada 45½” (1156mm) 48¼” (1226mm)
USA 43½” (1104mm) 46¼” (1175mm)
1700
Canada 45½” (1156mm) 52¾” (1340mm)
USA 43½” (1104mm) 50¾” (1290mm)
Top vent out
back wall
with min. 24”
(610mm) vertical
rise; double wall
1200
Canada 46½” (1181mm) 50¼” (1277mm)
USA 44½” (1129mm) 48¼” (1226mm)
1700
Canada 43½” (1104mm) 55¾” (1417mm)
USA 41½” (1053mm) 53¾” (13466mm)