Specifications
27
VENT TERMINATION LOCATIONS 
Letter Minimum Clearance  Description 
A  24" (60 cm)  Above grass, top of plants wood, or any other 
combustible material. 
B  48" (122 cm)  From beside/below any door or window that may be 
opened. 
C  24" (60 cm)  From any door or window that may be opened. 
D  24" (60 cm)  To any adjacent building, fence and protruding parts 
of the structure. 
E  24" (60 cm)  Below any eave or roof overhang. 
F  12" (30 cm)  To outside corner. 
G  12" (30 cm)  To inside corner, combustible wall. 
H  3' (91 cm) within a height of 15' (4.5 m) 
above the meter/regulator assembly 
To each side of center line extended above natural 
gas or propane meter/regulator assembly or 
mechanical vent. 
I  3' (91 cm)  From any forced air intake or other appliance. 
J  12" (30 cm)  Clearance to non-mechanical air supply inlet to 
building, or the combustion air inlet to any appliance. 
K  24" (60 cm)  Clearance above roof line for vertical terminations. 
L  7' (2.13 m)  Clearance above paved sidewalk or paved driveway 
located on public property. 
Figure 21 