9. AIR SHUTTER ADJUSTMENT 
•  There is a separate venturi air shutter for each burner 
•  The venturies have been set for installation at sea level to 4,500 ft. 
•  To adjust for higher altitudes: Remove the access cover plate, loosen the air shutter locking screws with a long screwdriver. 
Rotate the air shutters to the correct setting. The flame should be bright yellow in color and have a lively appearance. If 
sooting occurs on the glass then the venturi opening may need to be increased. 
11