Owner`s manual
24
Fan
White
BlackBlack
Black
Fan temperature
sensor
Black
Fan
controller
Power Supply
Black
Black
Rocker Switch
Manual
Auto
Off
Black
Installation
Figure 24: Fireplace Insert Fan Kit Wiring Diagram.
The Insert comes with the fan assembled installed
in the left shroud.
1) Disconnect all electrical connections for the fan
kit.
2) Remove the four (4) ½” hex head screws that
hold the fan mounting plate to the shroud.
3) Remove the fan control knob and nut from the
front of the shroud and pull the controls out the
back.
4) Install the fan kit into the new shroud by
following reversing steps 1 to 3. Refer to
fan
wiring diagraM to ensure the fan is reconnected
properly.
Fan remoVal:
Figure 25: Insert Unit with Fan.