Instructions / Assembly
12 / 20
PRE-USE INSTRUCTIONS
WARNING
!
Before using this outdoor fire table, make sure you have read, understand and are following all 
information provided in the Important Safety Information section of this manual. Failure to follow 
those instructions can cause death, serious injury or property damage.
Prior to each gas fireplace operation, check the hose and valve for evidence of excessive abrasion or 
wear though the visual check hole on the side of the base. Replace visual check cap prior to operating 
fireplace.
BURNER CONNECTIONS
Make sure the regulator valve and hose connections are securely fastened to the burner and the tank. 
If your unit was assembled for you, visually check the connection between the burner pipe and orifice. 
Make sure the burner pipe fits over the orifice.
WARNING
!
Failure to inspect this connection or follow these instructions could cause a fire or an explosion, 
which can cause death, serious bodily injury, or damage to property.
Please refer to diagram for proper installation.
If the burner pipe does not rest flush to the orifice please
contact Elementi at 800-678-7294 for assistance.
Checking for Leaks
Make a leak check solution by mixing 1-part dishwashing soap 
with 3 parts water in a spray bottle.
Make sure control knob is “OFF.” Then, turn natural gas on at 
its source.
Spray leak solution on valve connections paying particular 
attention to the areas indicated by arrows.
If any bubbles appear turn natural gas off, reconnectand
re-test. If you continue to see bubbles after several attempts,
disconnect natural gas source and contact Elementi 
at 800-678-7294 for assistance.
If no bubbles appear after one-minute turn source OFF, wipe 
away solution and proceed.
Check for leaks at these locations 