User's Manual

EZBee series Manual / Ver. 1.0
39
It is not necessary the receiver and sender have been set as same
communication mode. The communication mode is selected according to
the operating environment.
If a sender is set as Bypass mode and a receiver as ASCII mode, and
the sender sends a long message, the receiver can receive the message
as divided length of messages due to the size of internal buffer or
transmission delay.
For converting from the Bypass to ASCII mode, a string +++ should
be typed at least 300 [ msec] later after transmitting the final data. A
mode converting is succeeded if no characters are inputted during 300
[ msec] after inputting the string +++ . If any characters are inputted
within 300 [ msec] , it is considered as the transmitting data.