The possible values for each parameter are summarized as:
Parameter
value description
baud
2400, 9600, 19200, 38400,
57600, 115200
Baudrate possible to use
flow
0
No Hardware follow control
1
Use hardware follow control
When a very high baudrate is set, the data transmitted can be lost
because the I/ O buffer size of EZBee is 128 byte each. According, it is
recommended to use a hardware follow control. If it is difficult to use a
hardware follow control, the low baudrate such as under 9600 is
recommended strongly.
7.1.2
7.1.27.1.2
7.1.2 Echo mode setting
Echo mode settingEcho mode setting
Echo mode setting
The option for an echo according to the AT commands inputted are
selectable as shown as:
Command
Parameter Result Description
AT+E0
None
OK
Cancel echo mode
AT+E1
None
OK
Activate Echo mode
AT+E?
None
0
or
1
Check current echo option