User manual

-11--10-
Table 3 (Setup) :
Table 2.1(Parameters):
Monitor &
Speak
To enable Indoor Monitor under monitoring state
can speak to Door Staon at same me.
If set to 1, talk enabled; set to 0, disabled.
Monitor &
Unlock
Ring Numbers
To enable Monitors under monitoring state can
open the door at the same me.If set to 0, unlock
funcon is disabled; Set to 1, unlock is enable;
Set to 2,unlock is enable and close at once; Set to 3,
unlock is enable and close in 5s.
To show ring mes when door staon calls monitor.
4 opons for choice. If set to 0, ring once. If set to 1,
ring twice. If set to 2, ring three mes.
If set to 3,cycle ring.
NameList
Display Mode
To show the namelist display mode.If set to 0,
it's the DT-Config display mode.If set to 1,
it's the Simulate display mode
Working Mode
To show the working mode. If set to 0, it's the
apartment system mode.
If set to 1,it's the villa mode.
Wait Timing
Item Factory SetDescripon
Language 01
03
08
[0]
[88888888]
[1111]
To change language.the code format is 4 digits.
Please refer to part 5,secon 10 (change door staon
language) for more detail informaons.
Item Factory SetDescripon
Monitor Timing 30s
30s
90s
[1]
[1]
[0]
[0]
40s
To show the monitor me, Range from 6s to 600s
Switch Timing
To show the surveillance me for each Door Staon
or CCTV camera.Range from 6s to 600s
To show the calling wait me, Range from 10s to 600s
Talk Timing
To show the limitaon me of talking, Range from
10s to 600s
Note : This secon is set on DT-Config soware,for more detail informaons, please refer to
the DT-Config soware user instrucons.
Tone Select
Select the chime of Door Staon in calling wait state,
12 chord tunes are available, key in 01 to 12 to select.
Tone Volume
Adjust the tone volume for dooor staon in calling.
Range from 01~15
Unlock Code
To change unlock code in Common Code Unlock mode,
in 4-digits format. 1111 is the default unlock code.
Display Mode
To select the Door Staon screen menu .If set to 0,
the screen displays the visitor's image when talking.
If set to 1,the screen displays icons when talking.
Clock ...
To set date and me.
Date format:if set to 0,date format is DD/MM/YY,
if set to 1,date format is MM/DD/YY.
Time format: if set to 0, me format is 24 hour
standard.If set to 1,me format is12 hour standard.
Setup Code To change the Program Code.
About ...
1. Hardware version--To show the Door Staon
(including ACS) hardware informaon
2. Soware version--To show the Door Staon
(including ACS) soware informaon
3. Manufacture Date--To show the manufacturing date
4. Dialing Counts--To show the call operaon counts
5. Calls Counts--To show the established calling counts
6. Unlock Counts--To show the unlock operaon counts
7. Standby Voltage--To show the voltage that the door
staon in standby.
8. Working Voltage--To show the voltage that the door
staon in working.
9. Video Standard--PAL or NTSC standard
10. UI_CODE--To show the UI byte counts and check box
11. MCM-VER--To show the version and language for MCM
12. Updated--To show the updated me for UI
Default ...
Restore all Setup parameters to factory default seng,
Please note that this operaon is an irreversible