To check the voltage of the monitor,
note that the monitor must be online.
Item Submenu
1. Installer Setup
1. ID Code [0]
2. Unlock Timing [05]
3. Unlock Output [0]
4. Card Memory [0]
5. Doorplate Mode
6. Audio Opons ...
7. Parameters ...
8. Installer Code ...
9. Default ...
2. Setup
1. Language [1]
2. Tone Select [03]
3. Tone Volume [08]
4. Unlock Code [1111]
5. Display Mode
6. Clock ...
7. Setup Code ...
8. About ...
9. Default ...
3. Card Manage
1. Add Card ...
2. Delete By Card
3. Delete By M.code
4. Cards Informaon
5. Format
4. Online Monitors
To search the online monitors, input
the monitor code number to search
5. Online Devices
To search the online door staons.
Max.4 door staon can be searched
6. Voltage Measure
Item Factory SetDescripon
ID Code [0] Single
[66666666]
0
0
0
[05]
5 Seconds
If only one door staon is installed in this building,
set to 0 ;
If mul door staons are installed, primary door
staon must be set to 0, and other slave door
staons must be set from 1 to 3. Note that max.
4 door staons are available in one building
Unlock Timing
Unlock Output
Card Manage
Doorplate Mode
[0]
Auto mode
Audio Opons ...
Parameters ...
Installer Code ...
Default ...
To set the me that how long the door keeps open
when door is released. Range from 01 to 99 seconds.
To set the unlock mode to match the corresponding
lock.Range from 0 to 1.
0: Power-on-to-Unlock Mode(Normally Open Mode)
1: Power-off-to-Unlock Mode(Normally Closed Mode)
To set the card locaon.If set to 0,the card is saved
in door staon.If set to 1, the card is saved in DT-IPC
To set the calling mode. If set to 0,it's the auto mode,
that means the calling will be acvated directly aer
inpung 2 digits code.If set to 1, it's the manual
mode,that means you should press "#" buon to
acvate the calling aer inpung the code.
To set talking mode, when cung voice or mixed
voice appears, set to 1.
DS-IM talking:set the vioce matching between
DoorStaon and Indoor Monitor
DS-NT talking:set the vioce matching between Door
Staon and Guard Unit
To show the parameters,please refer to table 2.1
To change door staon administrator code
Note this operaon is irreversible. Once restore is
acvated, all parameters will return to factory default
seng except the informaon of access card.